Tc-99m sulfur colloid scintigraphy for detecting perigraft flow following endovascular aortic aneurysm repair: A feasibility study

Cardiovasc Intervent Radiol. 1999 Nov-Dec;22(6):447-51. doi: 10.1007/s002709900430.

Abstract

Purpose: To determine if scintigraphy with Tc-99m sulfur colloid can be used to detect perigraft flow after stent-graft repair of abdominal aortic aneurysm (AAA).

Methods: Twenty-three men and two women aged 56-84 years (mean 71 years) underwent endoluminal AAA repair as part of the EVT Phase II trial [EVT = Endovascular Technologies (Menlo Park, CA, USA)]. Aneurysm size averaged 5.4 cm (range 3-8 cm). Sixteen bifurcated, seven tube, and two aorto-uniiliac grafts were placed. Two days after stent-graft placement, patients underwent both contrast-enhanced computed tomography (CT), including delayed views, and Tc-99m sulfur colloid scintigraphy.

Results: Perigraft flow was found in only one patient at completion of angiography. Four additional patients had perigraft flow, discovered during their postoperative follow-up CT. Four patients had leaks at an attachment site and one had retrograde branch flow. Tc-99m sulfur colloid scintigraphy failed to diagnose any of the five leaks prospectively. In two of these patients, however, some abnormal paraaortic activity was noted in retrospect.

Conclusion: Tc-99m sulfur colloid scintigraphy was unable to demonstrate endoleak with either rapid flow (attachment site leak) or slow filling (branch flow).

Publication types

  • Clinical Trial
  • Clinical Trial, Phase II
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aortic Aneurysm, Abdominal / surgery*
  • Blood Vessel Prosthesis Implantation
  • Feasibility Studies
  • Female
  • Humans
  • Male
  • Postoperative Complications / diagnostic imaging*
  • Radionuclide Imaging
  • Radiopharmaceuticals
  • Stents
  • Technetium Tc 99m Sulfur Colloid*
  • Tomography, X-Ray Computed

Substances

  • Radiopharmaceuticals
  • Technetium Tc 99m Sulfur Colloid