Successful endoluminal thrombo-aspiration of renal graft venous thrombosis

Transpl Int. 2000;13(1):82-6. doi: 10.1007/s001470050014.

Abstract

Renal transplant vein thrombosis is an unusual event occurring in 0.3-3% of renal transplantations. Prognosis is uniformly poor with graft loss in nearly every case. We report here the first three cases of renal graft vein thrombosis successfully treated by percutaneous endoluminal thromboaspiration. After an initially uneventful course all recipients developed anuria and required hemodialysis. In two cases, an ultrasound examination suggested a diagnosis of venous thrombosis. Emergency arteriography and phlebography were performed, confirming the complete thrombosis of the graft veins. Thromboaspiration was carried out with full heparinization and led to renal function improvement in all cases. Grafts are still functioning 6 months after the procedure, with serum creatinine levels of 176 mumol/l, 120 mumol/l and 184 mumol/l, respectively. Thus, this procedure avoids surgical and anaesthetic risks and allows, if performed at an early stage, restoration of graft function. Great care must be taken to avoid vein wall damage, vascular suture line rupture, or pulmonary embolism.

Publication types

  • Case Reports

MeSH terms

  • Adult
  • Female
  • Graft Occlusion, Vascular / diagnostic imaging
  • Graft Occlusion, Vascular / therapy
  • Humans
  • Kidney Transplantation*
  • Male
  • Middle Aged
  • Postoperative Complications*
  • Radiography
  • Renal Veins*
  • Suction
  • Venous Thrombosis / diagnostic imaging
  • Venous Thrombosis / etiology
  • Venous Thrombosis / therapy*