Validated HPLC method for quantifying permethrin in pharmaceutical formulations

J Pharm Biomed Anal. 2001 Mar;24(5-6):999-1004. doi: 10.1016/s0731-7085(00)00544-6.

Abstract

An isocratic HPLC method for permethrin determination in raw material and pharmaceutical presentations as lotion and shampoo has been developed and validated following ICH recommendations. Cis and trans- isomers, impurities and degradation products are well separated. The chromatographic analysis were performed on a 4 microm particle C-18 Nova-Pak (Waters, Madrid, Spain) column (15 x 0.39 cm) kept in a Biorad column oven at 35 degrees C. Mobile phase consisted of methanol--water (78:22, v/v) at a flow rate of 1 ml/min. UV detection was performed at 272 nm and peaks were identified with retention times as compared with standards and confirmed with characteristic spectra using the photodiode array detector.

Publication types

  • Research Support, Non-U.S. Gov't
  • Validation Study

MeSH terms

  • Chromatography, High Pressure Liquid / methods*
  • Insecticides / analysis*
  • Permethrin
  • Pharmaceutical Preparations / chemistry*
  • Pyrethrins / analysis*
  • Spectrophotometry, Ultraviolet

Substances

  • Insecticides
  • Pharmaceutical Preparations
  • Pyrethrins
  • Permethrin