The personnel dosimetry department of the Greek Atomic Energy Commission (GAEC) assures the individual monitoring of almost 8000 occupationally exposed workers. Thermoluminescence dosimetry systems will replace the existing photographic dosimetry system for the individual monitoring with the joint support of IAEA and GAEC. The thermoluminescence dosimetry system consists of two automated readers, one automated irradiator and about 20,000 dosemeters purchased from the Rados Co. The properties of two thermoluminescent materials have been compared: LiF has been chosen for the whole-body dosemeter configuration and Li2B4O7 for the extremities. The technical evaluation of the system has been performed according to the European and IEC standards. The overall uncertainty has been calculated. The existing database system, and the accounting and dispatching procedures have been adapted to the new demands. The system became operational on March 2000, and the official distribution of thermoluminescence dosemeters has begun.