Atrial fibrillation surgery simplified with cryoablation to improve left atrial function

Ann Thorac Surg. 2001 Nov;72(5):1479-83. doi: 10.1016/s0003-4975(01)03176-9.

Abstract

Background: The Maze procedure restores atrial fibrillation to normal sinus rhythm. However, concurrent left atrial functional recovery is not always achieved. To address this limitation, a modification using linear cryoablation is described.

Methods: Between July 1997 and December 1999, 83 patients received atrial fibrillation surgery in association with mitral valve surgery with or without additional concurrent procedures by either the conventional technique, group I (n = 30) or the modified technique, group II (n = 53). Onset of sinus conversion and echocardiographic assessment of postoperative left ventricular function, left atrial size, and mitral A-wave velocity were compared in the early postoperative period and 6 months after surgery.

Results: Sinus conversion occurred significantly earlier in group II, 2.4 +/- 5 days versus group I, 7.0 +/- 10 days. The mean transmitral A-wave velocity and the incidence of A-wave appearance in the early postoperative period and 6 months postoperatively were greater in group II than group I.

Conclusions: With the current modification, restoration of sinus rhythm and superior left atrial contractile function occurred earlier than with the standard Maze III technique.

MeSH terms

  • Atrial Fibrillation / surgery*
  • Atrial Function
  • Cardiac Surgical Procedures / methods
  • Cryosurgery*
  • Female
  • Humans
  • Male
  • Middle Aged