[The influence factors of SO2 removal in flue gas with a pulsed corona discharge]

Huan Jing Ke Xue. 2001 Sep;22(5):38-40.
[Article in Chinese]

Abstract

The influence of the operation parameters on SO2 removal rate with a pulsed corona discharge was studied in this paper, in order to promote the industrial applications of this technology. The flow rate of the flue gas was 1000-3000 m3/h. The SO2 removal rate reached 80%. The range of SO2 concentration in flue gas was 1000-2000 ml/m3. The flue gas temperature was 60 degrees C-80 degrees C. The molecule ratio of NH3 to SO2 was 2. The energy consumption was 3-5 W.h/Nm3. The wire-plane electrode structure and a positive high voltage pulse power supply were used in the experiment.