Abstract
A neonate with pulmonary atresia and intact ventricular septum underwent a modified right sided Blalock-Taussig shunt. Following the procedure, the patient developed a right sided haemothorax, which required drainage. A murmur was not audible subsequently. Echocardiography with colour flow imaging enabled identification of patency of the right sided shunt. It was then possible to discontinue intravenous prostaglandin medication.
MeSH terms
-
Blood Vessel Prosthesis*
-
Ductus Arteriosus, Patent / complications
-
Ductus Arteriosus, Patent / surgery
-
Echocardiography, Doppler*
-
Humans
-
Hypertension, Pulmonary / etiology
-
Infant, Newborn
-
Infusions, Intravenous
-
Polytetrafluoroethylene
-
Prostaglandins / administration & dosage
-
Pulmonary Artery / abnormalities
-
Pulmonary Artery / surgery*
-
Subclavian Artery / surgery*
Substances
-
Prostaglandins
-
Polytetrafluoroethylene