To achieve the best reproducibility in rat brain tumour models several injection techniques have been used. Although stereotactic cell injections have proved to be effective and reliable, they are expensive and time consuming. A new permanently implanted device is presented here. It allows precise cell delivery for best tumour reproducibility, and it can be left in place for future injections at the exact same location, such as intratumoural chemotherapy. A Teflon tube was mounted on a disc, inserted into the rat brain and sealed to the skull. The device was tested in two rat strains (Wistar and New Zealand Nude rats) with two different glioma cell lines (9L and C6). Rats were treated with placebo to determine if repeated treatments had an effect on the device placement, or if device-related morbidity was induced. Analysis of brain sections showed that the device path was always within the tumour. The device never moved or came off the scalp. Both Wistar rats and NZ nude rats tolerated the device well. No morbidity or mortality was observed, regardless of the presence of the device; no infections were seen. Biocompatible, non-irritating and well tolerated, such a device can be used for reproducible tumour cell injections and repeated intralesional delivery of drugs.