Reduced high-frequency QRS components in patients with ischemic heart disease compared to normal subjects

J Electrocardiol. 2004 Jul;37(3):157-62. doi: 10.1016/j.jelectrocard.2004.02.004.

Abstract

Analysis of high-frequency QRS components (HF-QRS) might provide an additional method when diagnosing various heart diseases, for example ischemic heart disease (IHD). This study compares HF-QRS in normal subjects to those in patients with IHD, and also analyzes HF-QRS considering gender and age. A total of 63 normal subjects and 64 patients with IHD were included. Signal-averaged electrocardiograms (ECGs) from the 12 standard leads were analyzed in the frequency interval of 150-250 Hz. The results showed that the summed 12 lead HF-QRS in patients with IHD were significantly lower than in normal subjects (mean summed HF-QRS was 33.5 microV in the IHD group, 43.7 microV in normal individuals, P <.0005). HF-QRS were not statistically associated with gender or age (P =.820 and P =.573, respectively). However, the inter-individual variation of HF-QRS was large in both groups which probably limits the clinical usefulness of the method.

MeSH terms

  • Case-Control Studies
  • Electrocardiography* / methods
  • Female
  • Humans
  • Male
  • Middle Aged
  • Myocardial Ischemia / diagnosis*
  • Myocardial Ischemia / physiopathology
  • Signal Processing, Computer-Assisted