Long-term performance of transvenous, steroid-eluting, high impedance, passive-fixation ventricular pacing leads

Pacing Clin Electrophysiol. 2004 Oct;27(10):1399-404. doi: 10.1111/j.1540-8159.2004.00644.x.

Abstract

The long-term performance of two high impedance, steroid-eluting, passive-fixation ventricular leads, porous platinum iridium electrode CPI Selute Picotip 4035 (131 patients), and platinized platinum electrode Medtronic Capsure Z 5034 (57 patients), was compared with one conventional 8.0-mm2 porous platinum iridium electrode CPI Selute 4285 (38 patients). The mean follow-up period was 28 +/- 14 months. Capture threshold, R wave amplitude, and pacing impedance were measured at the time of implantation, immediately after implantation, 1 week, 1, 3, and 6 months after implantation and then every 6 months thereafter. The two high impedance leads revealed a higher sensing slew rate than the conventional lead, the R wave amplitude was similar among the three groups, but the voltage threshold at 0.5-ms pulse width was significantly higher in porous platinum iridium groups at the time of implantation. During follow-up, the conventional lead revealed a significantly higher R wave amplitude within the first 3 months, however, this pattern disappeared after 3 months. Pacing impedance was significantly higher in the high impedance porous platinum iridium electrode groups. Voltage threshold at 0.5-ms pulse width was similar among the three groups in the first 3 months, however, it increased gradually and was significantly higher in porous platinum iridium electrode groups subsequently. The energy threshold at 0.5 ms was significantly lower in the two high impedance groups than the conventional group, but no difference was found in the two high impedance groups. Lead related complications were similar among the three groups. In conclusion, high impedance electrodes with different design and materials had different properties; platinized platinum electrode showed a lower pacing impedance but had a more stable long-term capture threshold as compared to the porous platinum iridium electrode. Further studies are mandatory for the development of an ideal pacing lead.

Publication types

  • Clinical Trial
  • Comparative Study

MeSH terms

  • Aged
  • Drug Delivery Systems
  • Electric Impedance
  • Equipment Design
  • Female
  • Humans
  • Male
  • Middle Aged
  • Pacemaker, Artificial*
  • Steroids / administration & dosage
  • Time Factors

Substances

  • Steroids