Comparison of measurement of cross-sectional coronary atherosclerotic plaque and vessel areas by 16-slice multidetector computed tomography versus intravascular ultrasound

Am J Cardiol. 2004 Nov 15;94(10):1294-7. doi: 10.1016/j.amjcard.2004.07.117.

Abstract

In 26 patients, 16-slice multidetector computed tomography (MDCT) with 0.75-mm collimation and intravascular ultrasound (IVUS) of 1 coronary artery were performed. At 100 sites within the coronary arteries, the measurement of cross-sectional luminal area and, if detectable, the cross-sectional area of atherosclerotic plaque was performed independently with IVUS and MDCT. The mean luminal area (r = 0.92), measured at 100 sites, and plaque area (r = 0.55), measured at 65 sites, were significantly correlated (p <0.001) between MDCT and IVUS. The mean luminal area and mean plaque area were slightly but significantly overestimated with MDCT. MDCT permits the noninvasive measurement of coronary cross-sectional luminal and plaque areas with moderate accuracy.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Coronary Angiography*
  • Coronary Artery Disease / diagnostic imaging*
  • Coronary Vessels / diagnostic imaging*
  • Female
  • Humans
  • Image Processing, Computer-Assisted
  • Male
  • Middle Aged
  • Tomography, X-Ray Computed*
  • Ultrasonography, Interventional*