[Combination of open osteosynthesis and external fixator in distal multi-fragment joint fractures of the radius. Methodology and results]

Unfallchirurg. 1992 Feb;95(2):83-6.
[Article in German]

Abstract

The article describes the application to a minimal open screw-osteosynthesis combined with a fixateur externe following dislocated articular multifragment fracture of the radius. No extensive uncovering of the fragments was performed. The results seen at follow-up examination in 12 patients are presented.

MeSH terms

  • Adult
  • Combined Modality Therapy
  • External Fixators*
  • Female
  • Follow-Up Studies
  • Fracture Fixation, Internal / instrumentation*
  • Fractures, Open / diagnostic imaging
  • Fractures, Open / surgery*
  • Humans
  • Male
  • Middle Aged
  • Postoperative Complications / diagnostic imaging
  • Radiography
  • Radius Fractures / diagnostic imaging
  • Radius Fractures / surgery*
  • Wound Healing / physiology
  • Wrist Injuries / diagnostic imaging
  • Wrist Injuries / surgery*