Background: The coronary sinus (CS) and its branches may play a role in the genesis of various arrhythmias. Applications of radiofrequency energy within the CS may be necessary. Atrio-esophageal fistula has been recognized as a complication of ablation along the posterior left atrial wall.
Objectives: The purpose of this study was to describe the in vivo topographic anatomy of the CS, esophagus, and coronary arteries using computed tomography (CT).
Methods: Helical contrast CT of the heart with three-dimensional and endoscopic reconstructions was performed in 50 patients (28 men and 22 women; mean age 54 +/- 10 years). The images were reformatted to determine the relationships among the CS, adjacent blood vessels, and esophagus and to determine the nature and thickness of surrounding tissue layers.
Results: Mean CS ostium diameter was 12 +/- 4 mm, and mean thickness of the periosteal fat layer was 3 +/- 2 mm. In 40 of the 50 patients (80%), the esophagus was adjacent to the CS, starting 24 +/- 9 mm from the ostium, and remained in contact for a mean length of 7 +/- 5 mm. Mean thickness of the fat layer between the esophagus and CS was 1 +/- 1 mm, and mean thickness of the anterior wall of the esophagus was 3 +/- 2 mm. In 10 patients (20%), there was no contact between the esophagus and CS. In 40 patients (80%), the right coronary artery was less than 5 mm from the CS (minimum distance 1 +/- 1 mm) over a mean length of 17 +/- 11 mm. In all patients, the circumflex artery was less than 5 mm from the CS (minimum distance 1 +/- 0.4 mm) over a mean length of 16 +/- 9 mm in patients with right-dominant coronary circulation and over a mean length of 86 +/- 11 mm in patients with left-dominant coronary circulation.
Conclusion: The CS often lies very close to the esophagus and coronary arteries. During radiofrequency energy ablation in the CS, caution should be exercised to prevent injury to surrounding structures.