OSEM reconstruction, associated with temporal fourier and depth-dependant resolution recovery filtering, enhances results from sestamibi and 201Tl 16-interval gated SPECT

J Nucl Med. 2005 Nov;46(11):1789-95.

Abstract

Gated SPECT recorded with 16 intervals determines left ventricular (LV) ejection fraction more accurately than does gated SPECT recorded with 8 intervals but produces higher image noise. This study aimed to assess the results from sestamibi and (201)Tl 16-interval gated SPECT when both signal-to-noise ratio and spatial resolution were enhanced with an original method of reconstruction.

Methods: Forty patients with coronary artery disease underwent (201)Tl and sestamibi 16-interval gated SPECT and, to be used as a reference, cardiac MRI. Assessments of global and regional LV function provided by ordered-subsets expectation maximization (OSEM) with depth-dependant resolution recovery and temporal Fourier filtering were compared with those from conventional filtered backprojection (FBP) previously optimized by screening various filter frequencies and various temporal smoothing levels.

Results: For both tracers, LV ejection fraction was determined best when the association of OSEM with depth-dependant resolution recovery was used alone, with temporal Fourier filtering, or with a slight 2-frame temporal smoothing: Mean absolute values of relative errors ranged from 3.2% to 3.6% (4.0%-7.9% for FBP), and coefficient correlation ranged from 0.91 to 0.93 (0.70-0.91 for FBP). Among these 3 reconstruction methods, the association of OSEM with depth-dependant resolution recovery with temporal Fourier filtering provided the highest signal-to-noise ratio, with mean increases of 54% for sestamibi and 80% for (201)Tl when compared with FBP, and the best analysis of segmental contractility, with exact agreement rates with MRI being 73% for (201)Tl and 79% for sestamibi.

Conclusion: OSEM associated with temporal Fourier filtering and depth-dependant resolution recovery filtering enhances the LV function assessment provided by sestamibi and (201)Tl 16-interval gated SPECT and dramatically reduces image noise, a property that enhances and facilitates image interpretation.

Publication types

  • Comparative Study
  • Controlled Clinical Trial

MeSH terms

  • Algorithms
  • Coronary Artery Disease / complications
  • Coronary Artery Disease / diagnostic imaging*
  • Female
  • Fourier Analysis
  • Gated Blood-Pool Imaging / methods*
  • Humans
  • Image Enhancement / methods*
  • Image Interpretation, Computer-Assisted / methods
  • Male
  • Middle Aged
  • Radiopharmaceuticals
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Signal Processing, Computer-Assisted
  • Stroke Volume*
  • Technetium Tc 99m Sestamibi*
  • Thallium*
  • Time Factors
  • Tomography, Emission-Computed, Single-Photon / methods
  • Ventricular Dysfunction, Left / diagnostic imaging*
  • Ventricular Dysfunction, Left / etiology

Substances

  • Radiopharmaceuticals
  • thallium chloride
  • Technetium Tc 99m Sestamibi
  • Thallium