[Design and application of the framework to prevent fracture of the magnetic denture]

Shanghai Kou Qiang Yi Xue. 2005 Oct;14(5):456-8.
[Article in Chinese]

Abstract

Purpose: To investigate the methods to prevent magnetic denture from fracture.

Methods: 17 cases were selected and divided into group A and group B. 9 cases in group A only used resin base, 8 cases in group B were strengthened with frameworks. The rates of fracture or fissure in denture base were observed for 5 years, Chi(2) test was used for statistical analysis.

Results: In group A, 3 cases were found with damaged base, there was no fracture happened in group B. Chi(2) test showed that there was significant difference between the two groups (P<0.05).

Conclusion: Frameworks should be designed to improve the strength of the magnetic denture base. It is easy to manufacture and apply with satisfactory clinical effects.

MeSH terms

  • Dental Restoration Failure*
  • Denture Bases
  • Denture Design*
  • Humans
  • Magnetic Phenomena*
  • Materials Testing*