Comparison between sirolimus-eluting stents and intracoronary catheter-based beta radiation for the treatment of in-stent restenosis

Am J Cardiol. 2005 Dec 15;96(12):1656-62. doi: 10.1016/j.amjcard.2005.07.081. Epub 2005 Oct 21.

Abstract

We report the outcomes of patients who had in-stent restenosis (IRS) that was treated with intravascular brachytherapy (IVBT) or sirolimus-eluting stent (SES) implantation. The benefit of IVBT for treating ISR is well documented. SES implantation decreases first-time ISR and, in preliminary reports, has been used to treat ISR. Fifty consecutive patients who had ISR were treated; the first 25 patients underwent SES implantation and the next 25 patients were treated with IVBT using a beta-Cath System (a 40-mm strontium-90/yttrium-90 source). Quantitative angiographic and intravascular ultrasound follow-up were performed at 5.2 +/- 1.1 and 12.1 +/- 1.2 months; clinical follow-up was performed at 15 months. SES deployment and IVBT were successful in all patients. At 12-month follow-up, 8 patients who underwent IVBT had angiographic recurrence (4 in the stent and 4 at the stent edge); only 1 patient who underwent SES implantation developed recurrent ISR. At 12 months, in-stent late luminal loss was similar between the SES and IVBT groups (0.35 +/- 0.45 vs 0.34 +/- 0.46 mm, p = 0.9); however, in-stent net luminal gain was higher in the SES group than in the IVBT group (1.32 +/- 0.13 vs 0.57 +/- 0.19 mm, p <0.0001), and in-lesion late luminal loss was higher in the IVBT group (0.48 +/- 0.32 vs 0.16 +/- 0.42 mm, p = 0.004). At 12 months, intravascular ultrasound stent volume obstruction was higher after IVBT versus than after SES implantation (38.7% vs 6.7%, p <0.0001). At 15-month clinical follow-up, 64% and 96% (p <0.01) of patients who underwent IVBT and SES implantation, respectively, were free of major adverse cardiac events. In conclusion SES implantation for the treatment of ISR was effective and superior to catheter-based IVBT in preventing recurrent neointimal proliferation and angiographic restenosis at 1-year follow-up.

Publication types

  • Comparative Study

MeSH terms

  • Blood Vessel Prosthesis Implantation / instrumentation*
  • Brachytherapy / methods*
  • Catheterization, Peripheral
  • Coated Materials, Biocompatible*
  • Coronary Angiography
  • Coronary Restenosis / diagnostic imaging
  • Coronary Restenosis / therapy*
  • Coronary Vessels / diagnostic imaging
  • Coronary Vessels / drug effects
  • Coronary Vessels / radiation effects
  • Female
  • Follow-Up Studies
  • Graft Occlusion, Vascular / diagnostic imaging
  • Graft Occlusion, Vascular / therapy*
  • Humans
  • Immunosuppressive Agents / therapeutic use
  • Male
  • Middle Aged
  • Prospective Studies
  • Reoperation
  • Secondary Prevention
  • Sirolimus / therapeutic use*
  • Stents*
  • Treatment Outcome
  • Ultrasonography, Interventional

Substances

  • Coated Materials, Biocompatible
  • Immunosuppressive Agents
  • Sirolimus