Three-year follow-up after intracoronary beta-radiation therapy for in-stent restenosis

Catheter Cardiovasc Interv. 2006 Apr;67(4):600-6. doi: 10.1002/ccd.20667.

Abstract

Background: Most studies that proved intracoronary radiation therapy (IRT) to be highly effective to reduce recurrent restenosis after treatment of in-stent restenosis (ISR) have looked at time periods up to 12 months. Whether the beneficial effect from radiation is sustained during long-term follow-up remains a concern. This study sought to evaluate the effectiveness of IRT using a beta-emitter during a 3-year follow-up period.

Methods: One hundred twenty-eight consecutive symptomatic patients (mean age, 63 +/- 11 years) with 134 in-stent restenotic lesions were treated for ISR with IRT (noncentred beta-emitter, Novoste; radiation dosis 21.1 +/- 3.1 Gy). Six-month angiographic follow-up was obtained in 104 patients (81%) with 105 lesions (78%). All patients underwent 36-month clinical follow-up.

Results: Six-month angiographic restenosis rate was 22% in stent (29% in lesion) with an in-stent late loss of 0.49 +/- 0.62 mm. Target lesion resvascularization (TLR) at 6-month follow-up was performed in 23 cases (18%). MACE (death, myocardial infarction, and target vessel revascularisation) was observed in 24 patients (19%). At 36-month follow-up, TLR increased to 36 cases (28%) and MACE was observed in 47 patients (37%). In a multivariate analysis, minimal lumen diameter before treatment of ISR using IRT was the only predictor of recurrent TLR at 36 months (OR = 0.131; 95% CI, 0.068-0.254; p = 0.002). In a subgroup of patients (N = 15) without restenosis at 6-month angiography but with clinically driven recurrent late angiography (mean, 18 +/- 7 months); in-lesion late loss increased from 0.47 +/- 0.54 mm at 6 months to 1.27 +/- 0.76 mm at repeated angiography (p = 0.005).

Conclusion: There is a considerable number of delayed recurrent restenosis post IRT for ISR. This is due to ongoing late loss more than 6-month post IRT. The minimal lumen diameter before IRT predicts the need for recurrent TLR at 36 months.

MeSH terms

  • Aged
  • Beta Particles / therapeutic use
  • Brachytherapy*
  • Female
  • Follow-Up Studies
  • Graft Occlusion, Vascular / diagnostic imaging
  • Graft Occlusion, Vascular / etiology*
  • Graft Occlusion, Vascular / radiotherapy*
  • Humans
  • Male
  • Middle Aged
  • Prospective Studies
  • Radiography
  • Recurrence
  • Reoperation
  • Stents / adverse effects*
  • Time Factors
  • Treatment Outcome