The accuracy of MR imaging with Gd-DTPA enhancement was compared with mammography and ultrasonography in 52 patients with clinically palpable benign and malignant breast masses (36 carcinomas, 2 malignant phyllodes tumors, 7 fibroadenomas, 7 cysts). On dynamic MR imaging, carcinomas and fibroadenomas were discriminated by their different dynamic enhancement profiles. In carcinomas, signal intensity increased rapidly, reaching a peak or plateau within 2 min after the injection of contrast medium. In fibroadenomas, signal intensity showed a much slower continuous increase without ceasing until about 8 min after injection. Malignant phyllodes tumors showed a dynamic enhancement profile identical to that of benign fibroadenomas. MR imaging correctly identified 84% of malignant tumors, 86% of fibroadenomas, and 100% of cysts, and was substantially more accurate in tissue characterization than mammography. The results of ultrasonography were highly similar to those of MR imaging. However, no single modality was infallible, and the three modalities were complementary rather than competitive. Considering the high cost and long examination time of MR imaging, mammography supplemented by ultrasonography seems to be the method of choice in the diagnosis of breast lesions. Nevertheless, MR imaging can add important information when the results of mammography and ultrasonography are insufficient or contradictory.