Determination of respiratory phase during acquisition of airway cine MR images

Pediatr Radiol. 2006 Sep;36(9):965-9. doi: 10.1007/s00247-006-0241-z. Epub 2006 Jun 29.

Abstract

Subjects were imaged on a 1.5-T Signa MRI system using the head-neck vascular coil. An axial fast gradient echo cine, at the base of the second cervical vertebra, was obtained. A total of 128 images were acquired with a rapid image acquisition (one per second) over several respiratory cycles. The analog signal from the MR scanner (RF unblank) was utilized to determine the duration of the cine MR sequence. The phase of respiration was determined by analyzing the nasal air flow connected via pressure tubing to a pressure transducer outside the MR scanner room. We were thus able to determine the phase of respiration during acquisition of individual airway cine MR images. There was a wide range of airway volume measurements over the respiratory cycle with the lowest volume at end expiration and the highest at peak inspiration.

MeSH terms

  • Adolescent
  • Child
  • Female
  • Humans
  • Image Processing, Computer-Assisted
  • Magnetic Resonance Imaging, Cine / methods*
  • Male
  • Monitoring, Physiologic
  • Respiratory System / physiopathology*
  • Sleep Apnea, Obstructive / physiopathology*