Cost-effectiveness of defibrillator therapy or amiodarone in chronic stable heart failure: results from the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT)

Circulation. 2006 Jul 11;114(2):135-42. doi: 10.1161/CIRCULATIONAHA.105.581884. Epub 2006 Jul 3.

Abstract

Background: In the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT), implantable cardioverter-defibrillator (ICD) therapy significantly reduced all-cause mortality rates compared with medical therapy alone in patients with stable, moderately symptomatic heart failure, whereas amiodarone had no benefit on mortality rates. We examined long-term economic implications of these results.

Methods and results: Medical costs were estimated by using hospital billing data and the Medicare Fee Schedule. Our base case cost-effectiveness analysis used empirical clinical and cost data to estimate the lifetime incremental cost of saving an extra life-year with ICD therapy relative to medical therapy alone. At 5 years, the amiodarone arm had a survival rate equivalent to that of the placebo arm and higher costs than the placebo arm. For ICD relative to medical therapy alone, the base case lifetime cost-effectiveness and cost-utility ratios (discounted at 3%) were dollar 38,389 per life-year saved (LYS) and dollar 41,530 per quality-adjusted LYS, respectively. A cost-effectiveness ratio < dollar 100,000 was obtained in 99% of 1000 bootstrap repetitions. The cost-effectiveness ratio was sensitive to the amount of extrapolation beyond the empirical 5-year trial data: dollar 127,503 per LYS at 5 years, dollar 88,657 per LYS at 8 years, and dollar 58,510 per LYS at 12 years. Because of a significant interaction between ICD treatment and New York Heart Association class, the cost-effectiveness ratio was dollar 29,872 per LYS for class II, whereas there was incremental cost but no incremental benefit in class III.

Conclusions: Prophylactic use of single-lead, shock-only ICD therapy is economically attractive in patients with stable, moderately symptomatic heart failure with an ejection fraction < or = 35%, particularly those in NYHA class II, as long as the benefits of ICD therapy observed in the SCD-HeFT persist for at least 8 years.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Cost-Benefit Analysis
  • Death, Sudden, Cardiac* / epidemiology
  • Defibrillators, Implantable / economics*
  • Electroshock
  • Equipment Design
  • Heart Failure / surgery*
  • Humans
  • Medical Records
  • Randomized Controlled Trials as Topic / economics
  • Retrospective Studies
  • Treatment Outcome
  • United States / epidemiology