[Clinical usefulness of 201Tl/99mTc-PYP dual myocardial quantitative gated SPECT program using low-dose dobutamine loading in assessment of myocardial viability in patient with acute myocardial infarction--a case report]

Kaku Igaku. 2006 May;43(2):85-91.
[Article in Japanese]

Abstract

An 86-year-old man with chest pain was admitted to our hospital. Coronary angiography revealed 99% stenosis of the mid segment of the left anterior descending coronary artery, therefore, a coronary stent was implanted. Immediately after the stent implantation, 99% stenosis occurred at the proximal site of the 1st diagonal artery because of stent jeal. On the 4th hospital day, ECG-gated 201TL/99mTc-PYP dual myocardial quantitative gated SPECT was performed at rest and during low-dose dobutamine loading. The 201Tl scintigraphy revealed moderately reduced uptake in the anterior, septal and apical walls, and 99mTc-PYP uptake was observed in the mid-anterior wall. A three-dimensional surface display of gated 201Tl SPECT images showed severe hypokinesis in the anterior, septal and apical walls at rest. On the other hand, during low-dose dobutamine loading, improved wall motion was observed in the basal anterior and septal walls, while no change was observed in the midanterior and apical wall movements. Three-dimensional surface display of gated 201Tl/99mTc-PYP dual SPECT images revealed similar patterns of wall motion as those of gated 201Tl SPECT images at rest. During low-dose dobutamine loading, on the other hand, a three-dimensional surface display of gated 201Tl/99mTc-PYP dual SPECT images revealed improved wall motion in the basal anterior, septal and apical walls, but worsened wall motion of the mid-anterior wall. After 6 months, a follow-up coronary angiography revealed no re-stenosis of the stent, but 99% stenosis at the proximal aspect of the 1st diagonal artery. Left ventriculography revealed improved wall motion in the apex and akinesis of the mid-anterior wall. These wall motion findings were similar to those visualized in the three-dimensional surface display of gated 201Tl/99mTc-PYP dual SPECT images during low-dose dobutamine loading in the acute phase. These results suggest that 201Tl/99mTc-PYP dual myocardial quantitative gated SPECT using low-dose dobutamine loading could be useful for the assessment of myocardial viability after reperfusion therapy in patients with acute myocardial infarction.

Publication types

  • Case Reports

MeSH terms

  • Aged, 80 and over
  • Coronary Angiography
  • Coronary Artery Bypass
  • Dobutamine*
  • Gated Blood-Pool Imaging
  • Heart / diagnostic imaging*
  • Humans
  • Male
  • Myocardial Contraction*
  • Myocardial Infarction / diagnostic imaging*
  • Myocardial Infarction / physiopathology
  • Myocardial Infarction / surgery
  • Radiopharmaceuticals*
  • Stents
  • Technetium Tc 99m Pyrophosphate*
  • Tissue Survival
  • Tomography, Emission-Computed, Single-Photon

Substances

  • Radiopharmaceuticals
  • Dobutamine
  • Technetium Tc 99m Pyrophosphate