[Clinical effect of modified forsus appliance to children with mandibular retrusion]

Hua Xi Kou Qiang Yi Xue Za Zhi. 2006 Jun;24(3):246-9.
[Article in Chinese]

Abstract

Objective: To evaluate the effects of modified Forsus appliance in the treatment of Class II mandibular retrusion.

Methods: 18 children with mandibular retrusion were selected and treated with modified Forsus appliance. Cephalometric radiographs were taken and analyzed at pre-treatment and post-treatment. Students' t-test was used to determine if there were significant differences between pre-treatment and post-treatment.

Results: After 6-8 months of therapy, profiles were obviously improved. B moved forward (2.9+/-3.1) mm. ANB decreased (2.5+/-1.2) degrees. The overjet decreased (5.0+2.8) mm. The molar relationship was corrected to Class I from Class II. SN-OL increased (4.3+2.2) degrees. There was significant difference between pre-treatment and post-treatment.

Conclusion: Combined with straight wire appliance, modified Forsus appliance can effectively stimulate the mandibular growth, balance the jaw relationship, and correct mandibular retrusion.

MeSH terms

  • Cephalometry
  • Child
  • Female
  • Humans
  • Male
  • Malocclusion, Angle Class II
  • Mandible
  • Orthodontic Appliances, Functional*
  • Retrognathia*