Mechanical versus bioprosthetic valve replacement in middle-aged patients

Eur J Cardiothorac Surg. 2006 Sep;30(3):485-91. doi: 10.1016/j.ejcts.2006.06.013. Epub 2006 Jul 20.

Abstract

Objective: The current trend towards decreasing the age for selection of a tissue over a mechanical prosthesis has led to a dilemma for patients aged 50-65 years. This cohort study examines the long-term outcomes of mechanical versus bioprosthetic valves in middle-aged patients.

Methods: Patients (N = 659) aged between 50 and 65 years who had first-time aortic valve replacement (AVR) and/or mitral valve replacement (MVR) with contemporary prostheses were followed prospectively after surgery. The total follow-up was 3,402 patient-years (mean 5.1 +/- 4.1 years; maximum 18.3 years). Outcomes were examined with multivariate actuarial methods. A composite outcome of major adverse prosthesis-related events (MAPE) was defined as the occurrence of reoperation, endocarditis, major bleeding, or thromboembolism.

Results: Ten-year survival was 73.2 +/- 4.2% after mechanical AVR, 75.1 +/- 12.6% after bioprosthetic AVR, 74.1 +/- 4.6% after mechanical MVR, and 77.9 +/- 7.4% after bioprosthetic MVR (P=NS). Ten-year reoperation rates were 35.4% and 21.3% with aortic and mitral bioprostheses, respectively. Major bleeding occurred more often following mechanical MVR (hazard ratio [HR]: 3.3; 95% confidence interval [CI] 1.2, 9.0; P = 0.022), and the incidence of any thromboembolic event was more common after mechanical MVR (HR: 4.7; CI 1.4, 13.3; P = 0.01). Overall freedom from MAPE at 10 years was 70.2 +/- 4.1% for mechanical AVR patients, 41.0+/-30.3% for bioprosthetic AVR patients, 53.3 +/- 8.8% for mechanical MVR patients, and 61.2 +/- 9.2% for bioprosthetic MVR patients. Although a trend existed towards more MAPE amongst middle-age patients with tissue valves, multivariate analysis did not identify the presence of a bioprosthesis as an independent risk factor for MAPE (HR: 1.3; CI 0.9, 2.0; P = 0.22).

Conclusions: In middle-aged patients, MAPE may occur more often in patients with bioprosthetic valves, but definitive conclusions necessitate the accumulation of additional follow-up. At present, these data do not support lowering the usual cutoff for implantation of a tissue valve below the age of 65.

MeSH terms

  • Aged
  • Aortic Valve / surgery
  • Bioprosthesis*
  • Endocarditis / etiology
  • Female
  • Heart Valve Diseases / mortality
  • Heart Valve Diseases / surgery
  • Heart Valve Prosthesis
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / methods*
  • Heart Valve Prosthesis Implantation / mortality
  • Hemorrhage / etiology
  • Humans
  • Male
  • Middle Aged
  • Mitral Valve / surgery
  • Postoperative Complications / etiology
  • Prospective Studies
  • Reoperation
  • Stroke / etiology
  • Thromboembolism / etiology
  • Treatment Outcome