Value of PET/CT versus PET and CT performed as separate investigations in patients with Hodgkin's disease and non-Hodgkin's lymphoma

Eur J Nucl Med Mol Imaging. 2006 Dec;33(12):1417-25. doi: 10.1007/s00259-006-0171-x. Epub 2006 Jul 21.

Abstract

Purpose: The aim of this study was to assess the clinical benefit of combined [(18)F]FDG PET/CT in patients with malignant lymphoma as compared to separately performed PET and CT.

Methods: Overall, 100 patients with Hodgkin's disease (HD) or non-Hodgkin's lymphoma (NHL) were included in this study. Co-registered PET/CT with [(18)F]FDG and contrast medium was performed in 50 consecutive patients with NHL (n=38) or HD (n=12) for initial staging (IS) (n=12) or re-treatment staging (RS) (n=38). Another 50 patients with NHL (n=32) or HD (n=18) underwent separate PET and CT investigations within a time frame of 10 days for IS (n=22) or RS (n=28). Lymphoma involvement was separately evaluated for seven different regions in each patient. Each patient had clinical follow-up evaluation for >6 months. PET and CT data were analysed separately as well as side-by-side or in fused mode.

Results: In the PET/CT group, region-based evaluation for lymphoma involvement suggested a sensitivity/specificity of 85%/91% for CT, 98%/99% for PET and 98%/99% for PET/CT. In the PET and CT group, region-based evaluation showed a sensitivity/specificity of 87%/80% for CT, 98%/99% for PET and 98%/100% for PET and CT read side by side.

Conclusion: PET was superior to CT alone and was improved further by side-by-side reading of both examinations. However, no significant difference was observed between PET/CT and separate PET and CT imaging in patients with lymphoma.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Adult
  • Aged
  • Female
  • Hodgkin Disease / diagnostic imaging*
  • Hodgkin Disease / pathology
  • Humans
  • Lymphoma, Non-Hodgkin / diagnostic imaging*
  • Lymphoma, Non-Hodgkin / pathology
  • Male
  • Middle Aged
  • Neoplasm Staging
  • Positron-Emission Tomography / methods*
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed / methods*