Endovascular treatment of a coronary artery bypass graft to right ventricle fistula with balloon embolization

Int J Cardiol. 2006 Sep 20;112(2):e50-2. doi: 10.1016/j.ijcard.2006.03.071. Epub 2006 Jul 24.

Abstract

Fistula formation between a coronary artery bypass graft and a cardiac cavity is an uncommon finding. We describe a case of transcatheter occlusion of a coronary artery bypass graft to right ventricle fistula in a patient presenting with a subacute inferior myocardial infarction.

Publication types

  • Case Reports
  • Letter

MeSH terms

  • Aged
  • Balloon Occlusion*
  • Coronary Aneurysm / etiology
  • Coronary Aneurysm / therapy
  • Coronary Angiography
  • Coronary Artery Bypass / adverse effects*
  • Female
  • Fistula / etiology
  • Fistula / therapy*
  • Heart Diseases / etiology
  • Heart Diseases / therapy*
  • Heart Ventricles*
  • Humans
  • Myocardial Infarction / etiology
  • Saphenous Vein / transplantation