Recurrent aortic aneurysms following thoracic aortic stent-graft repair in a patient with Cogan syndrome

J Endovasc Ther. 2006 Dec;13(6):779-82. doi: 10.1583/06-1822MR.1.

Abstract

Purpose: To report the need for multiple surgical interventions to treat recurrent aortic aneurysms in a patient with Cogan syndrome.

Case report: A 17-year-old Chinese man with clinical Marfanoid features had a left common carotid artery pseudoaneurysm electively repaired with an autologous saphenous vein graft. Four months later, he presented with acute chest pain. Computed tomography (CT) revealed a 1-cm pseudoaneurysm at the mid descending aorta; a 24 x 100-mm Talent stent-graft was implanted to exclude the pseudoaneurysm. He was also found to have increasing left-sided hearing loss. A month later, the patient was re-admitted with vertigo and keratitis, which were treated appropriately. Nine months following stent-graft insertion, he was admitted with acute hemoptysis. Urgent CT showed a rupture at the proximal end of the stent-graft, with hemorrhage into the lung parenchyma. In an emergent procedure, the stent-graft was removed, and the descending thoracic aorta was repaired. Intraoperatively, a large pseudoaneurysm was found arising from the proximal part of the stented aorta, which appeared thickened. His postoperative recovery was uneventful. Nine months after the thoracotomy, a routine CT revealed an aneurysm at the distal descending thoracic aorta. On re-thoracotomy, a de novo saccular aneurysm was found 2.5 cm from the distal anastomosis. The affected segment was replaced with a Dacron graft. The distal aorta appeared thickened and edematous; histology confirmed aortitis. The patient was subsequently diagnosed with Cogan syndrome and given corticosteroids and methotrexate. There is no evidence of recurrence at nearly 2 years after the last intervention.

Conclusion: This case highlights the pitfalls of stent-graft repair in a patient with presumed connective tissue disease.

MeSH terms

  • Aneurysm, False* / diagnosis
  • Aneurysm, False* / etiology
  • Aneurysm, False* / therapy
  • Angioplasty, Balloon / methods*
  • Aortic Aneurysm, Thoracic* / diagnosis
  • Aortic Aneurysm, Thoracic* / etiology
  • Aortic Aneurysm, Thoracic* / therapy
  • Aortitis / complications
  • Aortography
  • Blood Vessel Prosthesis Implantation / methods*
  • Hearing Disorders / complications
  • Heart Bypass, Left
  • Humans
  • Keratitis / complications
  • Magnetic Resonance Imaging
  • Male
  • Recurrence
  • Reoperation
  • Stents*
  • Syndrome
  • Thoracotomy
  • Tomography, X-Ray Computed
  • Vertigo
  • Vestibular Diseases / complications