Objectives: To establish a Chinese national standard for a nucleic acid test (NAT) for HBV DNA.
Methods: The candidate sample of HBV DNA positive plasma was diluted with HBV-negative human plasma. The sample was lyophilised with a concentration of approximately 300,000 copies/ml. The measurement methods used included Roche Amplicor assay (version 2.0) and real-time PCR. The lyophilised preparation was calibrated by the international standard (NIBSC code: 97/746) from NIBSC.
Results: The quantity of this lyophilised preparation was (1.29+/-0.24) x 10(5)IU/ml in comparison with the international standard for HBV DNA 97/746. The stability test indicated that the sample was stable at room temperature (20 to 25 degrees C) for 2 weeks and at 37 degrees C for at least 1 week. Long-term stability was observed at 2 to 8 degrees C for 6 months and at -20 degrees C for more than 2 years with no significant changes. The vial-to-vial imprecision rate was 3.53%.
Conclusion: Based on the results of this study, our lyophilized sample can be used as a standard in China for the nucleic acid test (NAT) for HBV DNA.