Discrepant chromosome findings in placenta and fetus (false negative and false positive) after chorionic villus sampling (CVS) are mainly due to confined mosaicism. Non-mosaic normal or abnormal chromosome counts after direct preparation and culture nearly always correctly reflect the fetal chromosome constitution. False-negative results have almost exclusively been restricted to cytotrophoblast cells not representing a fetal chromosome abnormality. Diagnosis of placental mosaicism definitely requires an adequate follow-up by amniocentesis, fetal blood sampling, or sonography before a pregnancy is terminated. When direct preparations and cultured cells are used for cytogenetic diagnoses and placental mosaicism is not taken as proof for a chromosomal abnormality in the fetus, CVS is an accurate diagnostic tool.