Combined [18F]Fluorodeoxyglucose positron emission tomography and computed tomography (FDG-PET/CT) for detection of recurrent, 131I-negative thyroid cancer

Ann Surg Oncol. 2008 Jan;15(1):286-92. doi: 10.1245/s10434-007-9611-5. Epub 2007 Sep 20.

Abstract

Background: Whole-body (131)I scintigraphy (WBS) and serial thyroglobulin measurement (Tg) are standard methods for detecting thyroid cancer recurrence after total/near total thyroidectomy and (131)I ablation. Some patients develop elevated Tg (Tg-positive) or there is clinical suspicion of recurrence, but WBS are negative (WBS-negative). This may reflect non-iodine-avid recurrence or metastasis. In 2002, the Centers for Medicare and Medicaid Services (CMS) approved positron emission tomography with [(18)F]fluorodeoxyglucose (FDG-PET) for Tg-positive/WBS-negative patients with follicular-cell-origin thyroid cancer. Limited data are available regarding the performance of combined FDG-PET/computed tomography (FDG-PET/CT) for detecting recurrent thyroid cancer in WBS-neg patients.

Methods: This retrospective review of prospectively collected data analyzed 65 patients who had FDG-PET/CT for suspected thyroid cancer recurrence (April 1998-August 2006). Patients were WBS-negative but were suspected to have recurrence based on Tg levels or clinical grounds. Suspected FDG-PET/CT abnormalities were reported as benign or malignant. Lesions were ultimately declared benign or malignant by surgical pathology or clinical outcome (disease progression).

Results: Of 65 patients who underwent FDG-PET/CT, 47 had positive FDG-PET/CT. Of the positive FDG-PET/CT, 43 studies were true positives, with 21 (49%) confirmed pathologically by surgical resection. The four false positives (3/4 confirmed pathologically) included an infundibular cyst, an inflamed supraclavicular cyst, pneumonitis, and degenerative disc disease. Of the 18 FDG-PET/CT studies that were negative, 17 were true negatives and one was a false negative (metastatic papillary carcinoma). Thus, FDG-PET/CT demonstrated a patient-based sensitivity of 98%, specificity of 81%, positive predictive value of 91%, and negative predictive value of 94%.

Conclusions: FDG-PET/CT is useful for detecting thyroid cancer recurrence in WBS-negative patients, and can assist decision making.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Decision Making
  • False Negative Reactions
  • Female
  • Fluorodeoxyglucose F18*
  • Humans
  • Iodine Radioisotopes*
  • Male
  • Middle Aged
  • Neoplasm Recurrence, Local / diagnosis*
  • Positron-Emission Tomography*
  • Radiopharmaceuticals
  • Retrospective Studies
  • Sensitivity and Specificity
  • Thyroglobulin / analysis
  • Thyroid Neoplasms / diagnostic imaging*
  • Thyroid Neoplasms / pathology
  • Tomography, X-Ray Computed*
  • Whole Body Imaging

Substances

  • Iodine Radioisotopes
  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18
  • Thyroglobulin