Accuracy of 16-channel multi-detector row chest computed tomography with thin sections in the detection of metastatic pulmonary nodules

Eur J Cardiothorac Surg. 2008 Mar;33(3):473-9. doi: 10.1016/j.ejcts.2007.12.011. Epub 2008 Jan 25.

Abstract

Objectives: The inaccuracy of conventional CT makes open thoracotomy and manual palpation inevitable in pulmonary metastasectomy. However, the introduction of multi-detector row CT technology made it possible to detect pulmonary nodules with a diameter of 1mm. The purpose of this study was to investigate the accuracy of 1mm thin-section 16-channel multi-detector row CT (TSMDCT) in the detection of metastatic pulmonary nodules.

Methods: Twenty-seven patients who underwent pulmonary metastasectomy between November 2005 and September 2006 were included in the study. The primary tumors were colorectal cancer (n=11), renal cell carcinoma (n=5), osteosarcoma (n=3), hepatocellular carcinoma (n=3), thymic tumor (n=2), bladder cancer (n=1), thyroid cancer (n=1), and primitive neuroectodermal tumor (n=1). TSMDCT was performed in all patients in order to evaluate the location and number of metastatic nodules. The patients were divided into osteosarcoma and non-osteosarcoma groups, and the accuracy of TSMDCT was evaluated by comparison with the pathologic diagnosis of metastatic nodules.

Results: A total of 117 nodules were detected preoperatively by TSMDCT scanning, and 198 nodules were resected during the operation. A total of 101 nodules were pathologically confirmed to be metastatic nodules. In the osteosarcoma group, the sensitivity, specificity, positive predictive value, and negative predictive value were 34%, 93%, 92%, and 38%, respectively. In the non-osteosarcoma group, the sensitivity, specificity, positive predictive value, and negative predictive value were 97%, 54%, 64%, and 96%, respectively. Subgroup analysis in the non-osteosarcoma group revealed that nodule size over 5mm, number of metastatic nodules less than five, and disease-free interval over 24 months showed 100% sensitivity by preoperative TSMDCT.

Conclusions: TSMDCT with 1mm thickness image reconstruction showed high detection rate of metastatic pulmonary nodules in the patients with non-osteosarcoma. In highly selected subgroups, TSMDCT detected all the metastatic nodules which manual palpation could detect. Further study on the application of TSMDCT in thoracoscopic metastasectomy should be performed.

Publication types

  • Evaluation Study

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Female
  • Humans
  • Lung Neoplasms / diagnostic imaging*
  • Lung Neoplasms / secondary*
  • Lung Neoplasms / surgery
  • Male
  • Microtomy / methods*
  • Middle Aged
  • Predictive Value of Tests
  • Prospective Studies
  • Radiographic Image Interpretation, Computer-Assisted
  • Sensitivity and Specificity
  • Solitary Pulmonary Nodule / diagnostic imaging*
  • Solitary Pulmonary Nodule / secondary*
  • Solitary Pulmonary Nodule / surgery
  • Tomography, X-Ray Computed / methods*
  • Young Adult