Management of post-biopsy renal allograft arteriovenous fistulas with selective arterial embolization: immediate and long-term outcomes

Clin Radiol. 2008 Jun;63(6):657-65. doi: 10.1016/j.crad.2007.11.014. Epub 2008 Feb 20.

Abstract

Aim: To evaluate the outcomes after transcatheter embolization of percutaneous biopsy-related arteriovenous fistulas in renal allografts.

Materials and methods: All post-biopsy renal-transplant vascular injuries referred for embolization between June 1999 and October 2006 were reviewed retrospectively. There were six male and six female patients with a mean age of 49.8 years (range 25-67 years); nine patients were symptomatic, three asymptomatic. Colour Doppler ultrasound (CDUS) and angiography showed one intra-renal arteriovenous fistula in 10 patients and two in two patients, combined with a pseudoaneurysm in six patients. Superselective embolization using a single catheter or coaxial microcatheter was performed with 0.035'' coils or 0.018''microcoils, respectively, in all 12 cases. 24-h creatinine clearance values before (the day of biopsy) and after (7-14 days; 3 months) the procedure were compared using the Wilcoxon signed-rank test. Physical examination and CDUS were performed after 1, 6, and 12 months, and yearly thereafter. Mean follow-up was 33.6 months.

Results: Complete definitive occlusion of the fistula was achieved consistently with a single procedure. No procedure-related complications occurred. Renal infarction was minor in all patients (0-10% in nine and 10-20% in three). Symptoms resolved completely. Creatinine clearance values obtained before and after embolization were not statistically different (p=0.168;.889 respectively). No late recurrences were reported.

Conclusion: Transcatheter embolization with coaxial or single-catheter techniques was effective and safe for treating post-biopsy arteriovenous fistulas in renal transplants. The loss of renal parenchyma was minimal and no mid-term deterioration of allograft function was noted. The long-term survival of the renal allograft seemed to be not affected by embolization.

MeSH terms

  • Adult
  • Aged
  • Aneurysm, False / etiology
  • Arteriovenous Fistula / diagnostic imaging
  • Arteriovenous Fistula / etiology
  • Arteriovenous Fistula / therapy*
  • Biopsy / adverse effects
  • Creatinine / blood
  • Embolization, Therapeutic / methods*
  • Female
  • Humans
  • Kidney / pathology*
  • Kidney Transplantation / pathology*
  • Male
  • Middle Aged
  • Radiography
  • Renal Artery / diagnostic imaging
  • Retrospective Studies
  • Transplantation, Homologous
  • Treatment Outcome
  • Ultrasonography, Doppler, Color / methods

Substances

  • Creatinine