Objectives: In our previous study, scores determined via a multiple linear regression method (EN-MLR) involving an electronic nose provided objective halitosis-related measurements; however, this model afforded only relative expression exclusively. The objective of this investigation was to assess clinically oral malodor intensity expressed as an absolute value using an electronic nose.
Subjects and methods: Sixty-six subjects were evaluated based on results of an actual organoleptic test (OLT), measurements of volatile sulfur compound (VSC) concentrations, a score representing malodor intensity (EN-MI) as the absolute value and EN-MLR measured with an electronic nose system. Oral health parameters were also examined.
Results: The OLT score served as a benchmark. The area under the receiver-operating characteristic (ROC) plots of EN-MI score (0.975) was significantly larger than that of log VSC (0.896) (P = 0.036); however, the area did not differ significantly from that of EN-MLR score (0.932). Percentage of teeth with pocket depth greater than or equal to 4 mm, tongue coating score and plaque control record displayed meaningful association with EN-MI score in multiple logistic regression analyses.
Conclusion: Oral malodor intensity expressed as an absolute value employing an electronic nose may be a suitable method for clinical evaluation of oral malodor.