Contrast-enhanced transvaginal sonography of benign versus malignant ovarian masses: preliminary findings

J Ultrasound Med. 2008 Jul;27(7):1011-8; quiz 1019-21. doi: 10.7863/jum.2008.27.7.1011.

Abstract

Objective: The aim of this prospective study was to evaluate differences in contrast enhancement and contrast enhancement kinetics in benign versus malignant ovarian masses with pulse inversion harmonic transvaginal sonography.

Methods: Seventeen consecutive patients with 23 morphologically abnormal ovarian masses (solid or cystic with papillary excrescences, focally thickened walls, or irregular solid areas) smaller than 10 cm received a microbubble contrast agent intravenously while undergoing pulse inversion harmonic transvaginal sonography. The following parameters were assessed in all tumors: detectable contrast enhancement, time to peak enhancement (wash-in), peak contrast enhancement, half wash-out time, and area under the enhancement curve. Tumor histologic analysis was used to distinguish benign from malignant ovarian tumors.

Results: Fourteen benign masses and 9 malignancies were studied. There was a statistically significant difference in the peak enhancement (mean +/- SD, 23.3 +/- 2.8 versus 12.3 +/- 3.9 dB; P < .01), half wash-out time (139.9 +/- 43.6 versus 46.3 +/- 19.7 seconds; P < .01), and area under the enhancement curve (2012.9 +/- 532.9 versus 523.9 +/- 318 seconds(-1); P < .01) in malignant masses compared with benign disease. There was no statistically significant difference in the time to peak enhancement (26.1 +/- 6.3 versus 24.9 +/- 7.6 seconds; P = .07).

Conclusions: Overall, our data showed a significant difference in the contrast enhancement kinetic parameters between benign and malignant ovarian masses.

Publication types

  • Comparative Study
  • Evaluation Study
  • Research Support, N.I.H., Extramural

MeSH terms

  • Adenocarcinoma / diagnosis*
  • Adenocarcinoma / pathology
  • Adenocarcinoma / secondary
  • Adult
  • Aged
  • Area Under Curve
  • Breast Neoplasms / pathology*
  • Contrast Media*
  • Diagnosis, Differential
  • Endosonography / methods*
  • Female
  • Fluorocarbons
  • Humans
  • Image Enhancement / methods*
  • Image Processing, Computer-Assisted / methods
  • Kinetics
  • Microbubbles
  • Middle Aged
  • Ovarian Diseases / diagnosis
  • Ovarian Neoplasms / diagnosis*
  • Ovarian Neoplasms / pathology
  • Ovarian Neoplasms / secondary
  • Ovary / diagnostic imaging*
  • Prospective Studies
  • Reproducibility of Results
  • Ultrasonography, Doppler, Color / methods

Substances

  • Contrast Media
  • Fluorocarbons
  • perflutren