We describe emergency airway management with fiberoptic intubation in a patient in the prone position with her neck flexed by a head pin holder during a neurosurgical procedure. Laryngeal mask airway is suggested in emergency difficult airway algorithms; however, this was not feasible in this patient because of her edematous upper airway and limited mouth opening resulting from extreme neck flexion by a head pin holder. The case illustrates the role of fiberoptic intubation in emergency airway management in this critical situation. Maneuvers to facilitate fiberoptic technique are also described.