Treatment of a large postsurgical para-anastomotic aortic aneurysm using endovascular stent grafts. A case report with four-year follow-up

J Cardiovasc Surg (Torino). 2014 Jun;55(3):391-4. Epub 2008 Oct 24.

Abstract

This case report describes the outcome of straight endograft placement for treating a large para-anastomotic aortic aneurysm (PAA). A 43-year-old woman was admitted to the emergency department because of a vast PAA (8.7 cm in maximum transverse diameter). Since 1983, she has undergone multiple vascular operations for arterial occlusive disease. In 1990, an aortobifemoral bypass operation was performed. In this most recent intervention, we implanted three tube Excluder® endografts. The procedure was uneventful. Considering the size of the aneurysm sac, particular attention was paid to possible sequelae during the over 4-year follow-up period. No complications developed and the last computed tomography (CT) scan showed a remarkable decrease of 50 mm in aneurysm size. In conclusion, the use of straight endografts seems to be effective and lasting, even in large para-anastomotic aneurysmatic lesions.

Publication types

  • Case Reports

MeSH terms

  • Adult
  • Aortic Aneurysm / diagnosis
  • Aortic Aneurysm / etiology
  • Aortic Aneurysm / surgery*
  • Aortography / methods
  • Arterial Occlusive Diseases / surgery*
  • Blood Vessel Prosthesis Implantation / adverse effects
  • Blood Vessel Prosthesis Implantation / instrumentation*
  • Blood Vessel Prosthesis*
  • Endovascular Procedures / instrumentation*
  • Female
  • Humans
  • Prosthesis Design
  • Reoperation
  • Stents*
  • Time Factors
  • Tomography, X-Ray Computed
  • Treatment Outcome