Effects of center frequency and rate on the sensitivity to interaural delay in high-frequency click trains

J Acoust Soc Am. 2009 Jun;125(6):3903-13. doi: 10.1121/1.3120413.

Abstract

The effects of center frequency and pulse rate on the sensitivity to ongoing envelope interaural time differences (ITDs) were investigated using bandpass-filtered pulse trains. Three center frequencies (4.6, 6.5, and 9.2 kHz) were tested with bandwidths scaled to stimulate an approximately constant range on the basilar membrane. The pulse rate was varied from 200 to 588 pps (pulses per seconds). Five normal-hearing (NH) subjects were tested. Averaged over all rates, the results show a small decrease in sensitivity with increasing center frequency. For all center frequencies, sensitivity decreases with increasing pulse rate, yielding a rate limit of approximately 500 pps. The lack of an interaction between pulse rate and center frequency indicates that auditory filtering was not the rate limiting factor in ITD perception and suggests the existence of other limiting mechanisms, such as phase locking or more central processes. It is concluded that the comparison of the rate limits in ITD perception between cochlear-implant listeners and NH subjects listening to high-frequency bandpass-filtered pulse trains is not confounded by the choice of center frequency of stimulation in NH listeners.

MeSH terms

  • Acoustic Stimulation*
  • Acoustics
  • Adult
  • Analysis of Variance
  • Auditory Perception*
  • Auditory Threshold
  • Ear
  • Humans
  • Neuropsychological Tests
  • Psychoacoustics
  • Psychometrics
  • Task Performance and Analysis
  • Time Factors