[Retrospective 5-year analysis of MR-guided biopsies in a low-field MR system]

Rofo. 2009 Jul;181(7):658-63. doi: 10.1055/s-0028-1109349. Epub 2009 Jun 10.
[Article in German]

Abstract

Purpose: The purpose of this study was to evaluate the safety and clinical value of MR-guided biopsies in an open 0.2 T low-field system.

Materials and methods: A total of 322 patients with suspicious lesions of different body regions were biopsied in a low-field MRI system (0.2 T, Concerto, Siemens). The procedures were guided using T 1-weighted Flash sequences (TR/TE = 100/9; 70 degrees). The lesions were repeatedly biopsied using the coaxial technique with a 15-gauge (diameter 2 mm) puncture needle. Complications and biopsy findings were analyzed retrospectively.

Results: In all cases the biopsy procedures were successfully performed with MR guidance. In 298 patients diagnosis was able to be confirmed on the basis of the probes. The clinical follow-up showed that in 24 patients the lesions were missed by MR-guided biopsy. From this a sensitivity of 86%, a specificity of 87% and an accuracy of 93% were calculated. In two patients major complications were observed (morbidity rate 0.6 %).

Conclusion: MR-guided biopsy can be performed safely and precisely in a low-field MR system and are a supplement to US or CT-guided biopsies.

Publication types

  • English Abstract

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Biopsy, Needle / methods*
  • Child
  • Diagnosis, Differential
  • Female
  • Humans
  • Image Processing, Computer-Assisted / methods*
  • Magnetic Resonance Imaging, Interventional / methods*
  • Male
  • Middle Aged
  • Neoplasms / pathology*
  • Retrospective Studies
  • Sensitivity and Specificity
  • Young Adult