Advanced heart failure treated with continuous-flow left ventricular assist device

N Engl J Med. 2009 Dec 3;361(23):2241-51. doi: 10.1056/NEJMoa0909938. Epub 2009 Nov 17.

Abstract

Background: Patients with advanced heart failure have improved survival rates and quality of life when treated with implanted pulsatile-flow left ventricular assist devices as compared with medical therapy. New continuous-flow devices are smaller and may be more durable than the pulsatile-flow devices.

Methods: In this randomized trial, we enrolled patients with advanced heart failure who were ineligible for transplantation, in a 2:1 ratio, to undergo implantation of a continuous-flow device (134 patients) or the currently approved pulsatile-flow device (66 patients). The primary composite end point was, at 2 years, survival free from disabling stroke and reoperation to repair or replace the device. Secondary end points included survival, frequency of adverse events, the quality of life, and functional capacity.

Results: Preoperative characteristics were similar in the two treatment groups, with a median age of 64 years (range, 26 to 81), a mean left ventricular ejection fraction of 17%, and nearly 80% of patients receiving intravenous inotropic agents. The primary composite end point was achieved in more patients with continuous-flow devices than with pulsatile-flow devices (62 of 134 [46%] vs. 7 of 66 [11%]; P<0.001; hazard ratio, 0.38; 95% confidence interval, 0.27 to 0.54; P<0.001), and patients with continuous-flow devices had superior actuarial survival rates at 2 years (58% vs. 24%, P=0.008). Adverse events and device replacements were less frequent in patients with the continuous-flow device. The quality of life and functional capacity improved significantly in both groups.

Conclusions: Treatment with a continuous-flow left ventricular assist device in patients with advanced heart failure significantly improved the probability of survival free from stroke and device failure at 2 years as compared with a pulsatile device. Both devices significantly improved the quality of life and functional capacity. (ClinicalTrials.gov number, NCT00121485.)

Publication types

  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Actuarial Analysis
  • Adult
  • Aged
  • Aged, 80 and over
  • Cause of Death
  • Female
  • Heart Failure / mortality
  • Heart Failure / therapy*
  • Heart-Assist Devices* / adverse effects
  • Humans
  • Kaplan-Meier Estimate
  • Male
  • Middle Aged
  • Proportional Hazards Models
  • Prosthesis Design
  • Prosthesis Failure
  • Quality of Life
  • Stroke / etiology
  • Stroke / mortality
  • Stroke Volume

Associated data

  • ClinicalTrials.gov/NCT00121485