Coronary MR imaging: effect of timing and dose of isosorbide dinitrate administration

Radiology. 2010 Feb;254(2):401-9. doi: 10.1148/radiol.09090483.

Abstract

Purpose: To quantify the effect of sublingual isosorbide dinitrate (ISDN) administration on coronary magnetic resonance (MR) imaging.

Materials and methods: Written informed consent was obtained from all participants, and the HIPAA-compliant protocol was approved by the Institutional Review Board. Coronary MR imaging was performed at 1.5 T before and after administration of ISDN (2.5 or 5 mg) in 25 healthy adult volunteers (mean age, 23 years +/- 4; nine men, 16 women) with three-dimensional targeted (n = 20, randomized into four groups) or whole-heart (n = 5) acquisitions with gradient-recalled echo (GRE) or balanced steady-state free precession (SSFP) sequences. Image quality was assessed by two cardiologists on a four-point scale. Signal-to-noise ratio (SNR), vessel diameter, and vessel sharpness were characterized. A linear mixed-effects model was used for data analysis. A P value of less than .05 was considered to indicate a significant difference.

Results: The maximum SNR enhancement with 5 mg of ISDN (GRE: 22.0% +/- 10.7%; SSFP: 20.1% +/- 6.0%) was similar (P > .05) to that with 2.5 mg (GRE: 21.9% +/- 5.4%; SSFP: 19.1% +/- 3.0%). However, the time to maximum SNR enhancement for the 5-mg dose (15.5 minutes +/- 6.0) was earlier (P < .01) than that for 2.5 mg (23.5 minutes +/- 6.7). The increase in vessel diameter with 5 mg of ISDN was greater than that with 2.5 mg (P < .05 for both GRE and SSFP sequences). The coronary images were sharper after ISDN administration (P < .03). Subjective image quality score significantly improved after ISDN administration for GRE images (P < .05 for both doses) but was similar for SSFP images (P = .24 for 2.5 mg; P = .27 for 5 mg). Whole-heart coronary SNR was improved about 10% after ISDN administration (P < .05).

Conclusion: Sublingual ISDN improves coronary MR imaging SNR. Practitioners need to consider the dose and temporal effects of ISDN when performing coronary MR imaging.

Publication types

  • Randomized Controlled Trial
  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Administration, Sublingual
  • Coronary Vessels / anatomy & histology*
  • Female
  • Heart / anatomy & histology*
  • Humans
  • Image Enhancement / methods
  • Isosorbide Dinitrate / administration & dosage*
  • Linear Models
  • Magnetic Resonance Imaging / methods*
  • Male
  • Vasodilator Agents / administration & dosage*
  • Young Adult

Substances

  • Vasodilator Agents
  • Isosorbide Dinitrate