A novel diagnostic immunoassay testing procedure for hepatitis B virus core antibody (anti-HBc) using homogeneous purified full-length hepatitis B virus core antigen (HBcAg) capsids obtained from Escherichia coli was compared with Abbott Architect anti-HBc chemiluminescent microparticle immunoassay (CMIA; indirect method) against a library of specimens. A monoclonal anti-HBc neutralization confirmatory assay was then used to determine the degree of discordance between specimens. The new assay was found to be superior in both sensitivity and specificity.