Late safety, efficacy, and cost-effectiveness of a zotarolimus-eluting stent compared with a paclitaxel-eluting stent in patients with de novo coronary lesions: 2-year follow-up from the ENDEAVOR IV trial (Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions)

JACC Cardiovasc Interv. 2009 Dec;2(12):1208-18. doi: 10.1016/j.jcin.2009.10.008.

Abstract

Objectives: The aim of this study was to assess, after 2 years of follow-up, the safety, efficacy, and cost-effectiveness of a zotarolimus-eluting stent (ZES) compared with a paclitaxel-eluting stent (PES) in patients with native coronary lesions.

Background: Early drug-eluting stents were associated with a small but significant incidence of very late stent thrombosis (VLST), occurring >1 year after the index procedure. The ZES has shown encouraging results in clinical trials.

Methods: The ENDEAVOR IV trial (Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions), a randomized (1:1), single-blind, controlled trial (n = 1,548) compared ZES versus PES in patients with single de novo coronary lesions. Two-year follow-up was obtained in 96.0% of ZES and 95.4% of PES patients. The primary end point was target vessel failure (TVF), and safety end points included Academic Research Consortium-defined stent thrombosis. Economic end points analyzed included quality-adjusted survival, medical costs, and relative cost-effectiveness of ZES and PES.

Results: The TVF at 2 years was similar in ZES and PES patients (11.1% vs. 13.1%, p = 0.232). There were fewer myocardial infarctions (MIs) in ZES patients (p = 0.022), due to fewer periprocedural non-Q-wave MIs and fewer late MIs between 1 and 2 years. Late MIs were associated with increased VLST (PES: 6 vs. ZES: 1; p = 0.069). Target lesion revascularization was similar comparing ZES with PES (5.9% vs. 4.6%; p = 0.295), especially in patients without planned angiographic follow-up (5.2% vs. 4.9%; p = 0.896). The cost-effectiveness of ZES and PES was similar.

Conclusions: After 2 years of follow-up, ZES demonstrated efficacy and cost-effectiveness comparable to PES, with fewer MIs and a trend toward less VLST. (The ENDEAVOR IV Clinical Trial: A Trial of a Coronary Stent System in Coronary Artery Lesions; NCT00217269).

Publication types

  • Comparative Study
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Angioplasty, Balloon, Coronary / adverse effects
  • Angioplasty, Balloon, Coronary / instrumentation*
  • Angioplasty, Balloon, Coronary / mortality
  • Cardiovascular Agents / administration & dosage*
  • Constriction, Pathologic / etiology
  • Coronary Angiography
  • Coronary Artery Disease / diagnostic imaging
  • Coronary Artery Disease / mortality
  • Coronary Artery Disease / therapy*
  • Cost-Benefit Analysis
  • Drug-Eluting Stents*
  • Female
  • Health Care Costs*
  • Humans
  • Kaplan-Meier Estimate
  • Male
  • Middle Aged
  • Models, Economic
  • Myocardial Infarction / etiology
  • Paclitaxel / administration & dosage*
  • Prospective Studies
  • Prosthesis Design
  • Quality of Life
  • Quality-Adjusted Life Years
  • Risk Assessment
  • Single-Blind Method
  • Sirolimus / administration & dosage
  • Sirolimus / analogs & derivatives*
  • Time Factors
  • Treatment Outcome
  • United States

Substances

  • Cardiovascular Agents
  • zotarolimus
  • Paclitaxel
  • Sirolimus

Associated data

  • ClinicalTrials.gov/NCT00217269