A competitive indirect enzyme-linked immunoassay for lead ion measurement using mAbs against the lead-DTPA complex

Environ Pollut. 2010 May;158(5):1376-80. doi: 10.1016/j.envpol.2010.01.002. Epub 2010 Feb 4.

Abstract

Immunoassays for quantitative measurement of environmental heavy metals offer several advantages over other traditional methods. To develop an immunoassay for lead, Balb/c mice were immunized with a lead-chelate-protein conjugate to allow maximum exposure of the metal to the immune system. Three stable hybridoma cell lines were obtained through spleen cells fusion with Sp2/0 cells. One cell line, 2A11D11, produced mAbs with preferential selectivity and sensitivity for Pb-DTPA than DTPA, exhibiting an affinity constant of 3.34 + or - 0.24 x 10(9) M(-1). Cross reactivity (CR) with other metals were below 1%, except for Fe(III) with a CR less than 5%. This quantitative indirect ELISA for the lead ion was used to detect environmental lead content in local water sources; importantly, the results from the immunoassay were in excellent agreement with those from ICP-MS. Development of immunoassays for metal ions may thus facilitate the detection and regulation of environmental pollution.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Antibodies, Monoclonal / analysis*
  • Cell Line
  • Environmental Pollutants / analysis*
  • Enzyme-Linked Immunosorbent Assay / methods*
  • Lead / analysis*
  • Mice
  • Mice, Inbred BALB C
  • Pentetic Acid / analysis*

Substances

  • Antibodies, Monoclonal
  • Environmental Pollutants
  • Lead
  • Pentetic Acid