Radiation dose-volume effects in the stomach and small bowel

Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S101-7. doi: 10.1016/j.ijrobp.2009.05.071.

Abstract

Published data suggest that the risk of moderately severe (>or=Grade 3) radiation-induced acute small-bowel toxicity can be predicted with a threshold model whereby for a given dose level, D, if the volume receiving that dose or greater (VD) exceeds a threshold quantity, the risk of toxicity escalates. Estimates of VD depend on the means of structure segmenting (e.g., V15 = 120 cc if individual bowel loops are outlined or V45 = 195 cc if entire peritoneal potential space of bowel is outlined). A similar predictive model of acute toxicity is not available for stomach. Late small-bowel/stomach toxicity is likely related to maximum dose and/or volume threshold parameters qualitatively similar to those related to acute toxicity risk. Concurrent chemotherapy has been associated with a higher risk of acute toxicity, and a history of abdominal surgery has been associated with a higher risk of late toxicity.

Publication types

  • Meta-Analysis
  • Review

MeSH terms

  • Antineoplastic Combined Chemotherapy Protocols / adverse effects
  • Humans
  • Intestine, Small / diagnostic imaging
  • Intestine, Small / radiation effects*
  • Models, Biological
  • Radiation Injuries / complications*
  • Radiation Tolerance
  • Radiography
  • Radiotherapy Dosage
  • Risk
  • Stomach / diagnostic imaging
  • Stomach / radiation effects*