Technetium-99m(V)thiocyanate was evaluated as a radio-pharmaceutical for measuring gastric emptying of fat. Olive oil was labeled with 99mTc(V)thiocyanate by direct extraction from acidic thiocyanate solution. After incubation with dilute HCl (pH 1.4) at 37 degrees C for 3 hr, approximately 5% of the total radioactivity eluted into the aqueous phase. When incubated with human gastric juice (pH 1.8 and 2.2), approximately 8% of the activity was detected in the aqueous phase at 3 hr. Scintigraphic studies performed in two rabbits showed that olive oil labeled with 99mTc(V)thiocyanate emptied slowly from the stomach, with a gastric half-emptying time (T50) of more than 3 hr. A low-nutrient soup labeled with 113mIn-DTPA and mixed with 99mTc(V)thiocyanate labeled oil was consumed by six human volunteers. The oil emptied much more slowly (p less than 0.02) (median T50 = 198 min) than the aqueous component (median T50 = 30 min). These observations indicate that 99mTc(V)thiocyanate is a suitable pharmaceutical to measure gastric emptying of extracellular fat.