Cryoablation with an 8-mm tip catheter for pediatric atrioventricular nodal reentrant tachycardia is safe and efficacious with a low incidence of recurrence

Pacing Clin Electrophysiol. 2010 Jun 1;33(6):681-6. doi: 10.1111/j.1540-8159.2010.02706.x. Epub 2010 Mar 5.

Abstract

Background: Cryoablation with 4- and 6-mm tip ablation catheters has been demonstrated to be safe and effective in the treatment of atrioventricular nodal reentrant tachycardia (AVNRT) in pediatric patients, albeit with a higher rate of clinical recurrence. Limited information is available regarding efficacy, mid-term outcomes, and complications related to the use of the 8-mm Freezor Max Cryoablation catheter (Medtronic, Minneapolis, MN, USA) in pediatric patients.

Methods: We performed a retrospective review of all pediatric patients with normal cardiac anatomy who underwent an ablation procedure for treatment of AVNRT using the 8-mm tip Cryoablation catheter at three large pediatric academic arrhythmia centers.

Results: Cryoablation with an 8-mm tip catheter was performed in 77 patients for treatment of AVNRT (female n = 40 [52%], age 14.8 +/- 2.2 years, weight 62.0 +/- 13.9 kg). Initial procedural success was achieved in 69 patients (69/76, 91%). Transient second- or third-degree atrioventricular (AV) block was noted in five patients (6.5%). There was no permanent AV block. Of the patients successfully ablated with Cryotherapy, there were two recurrences (2/70, 2.8%) over a follow-up of 11.6 +/- 3.3 months.

Conclusion: Cryoablation with an 8-mm tip ablation catheter is both safe and effective with a low risk of recurrence for the treatment of AVNRT in pediatric patients.

Publication types

  • Multicenter Study

MeSH terms

  • Adolescent
  • Atrioventricular Block / etiology
  • Child
  • Cryosurgery / methods*
  • Female
  • Humans
  • Male
  • Recurrence
  • Retrospective Studies
  • Tachycardia, Atrioventricular Nodal Reentry / complications
  • Tachycardia, Atrioventricular Nodal Reentry / surgery*
  • Treatment Outcome