As for the pathologic conditions of neck lymph nodes, the clinician needs to know if the involved node is reactive, phlogistic, or neoplastic in nature. If accurate tumor staging is required, imaging techniques play a fundamental role. Our study was aimed at assessing the actual role of MR imaging in the evaluation of neck lymph node involvement. The study was performed using an MR Max Plus by General Electrics operating with an 0.5 T superconductive magnet. We employed gradient-echo (GE) pulse sequences with TR 500, TE 15 ms and 90 degrees flip angle for T1-weighted images, and with TR 500, TE 30 ms and 25-30 degrees flip angles for T2-weighted images; for Pd-T2-weighted images, TR was 520, TE 30 ms, and flip angles were 40-45 degrees. The results were correlated with histopathologic findings obtained at biopsy. The advantages of GE sequences were: 1) whole neck imaging--thus saving time, and reducing radiation dose and contrast media; 2) optimal anatomical and topographic evaluation of the lesion; 3) imaging of the longitudinal diameter of the node; 4) higher sensitivity for lymph node tissue modifications; 5) imaging of necrosis, hemorrhage, and/or fibrosis. GE sequences were especially useful for accurate tumor staging, in the follow-up, and to verify response to therapy. However, even though MR imaging has proven to have high sensitivity, its specificity was similar to that of contrast-enhanced CT. Further studies with the use of paramagnetic contrast media are needed to solve these problems.