Close connection between improvement in left ventricular function by cardiac resynchronization therapy and the incidence of arrhythmias in cardiac resynchronization therapy-defibrillator patients

Eur J Heart Fail. 2010 Dec;12(12):1325-32. doi: 10.1093/eurjhf/hfq171. Epub 2010 Oct 5.

Abstract

Aims: The aim of this study was to determine the relationship between improved ejection fraction (EF) and occurrence of arrhythmias in patients with cardiac resynchronization therapy devices with defibrillator function (CRT-D). The hypothesis was that patients who experienced a marked improvement in EF also had fewer appropriate defibrillator interventions.

Methods and results: We analysed data of 270 patients from 2 prospective registries with follow-up of ≥12 months and echocardiography performed ≥8 months after CRT-D implantation. The discriminator was whether left ventricular ejection fraction (LVEF) improved to >35% [cut-off for primary prevention implantable cardioverter-defibrillator (ICD) implantation]. Mean age was 61±11 years, LVEF 22±5%, and follow-up 40±22 months. Ischaemic cardiomyopathy was present in 48%, and secondary prevention indication was present in 25%. Implantable cardioverter-defibrillator interventions were delivered to 35% of patients. Echocardiography (20±15 months after implantation) showed an improvement in LVEF from 22% (SD 5.4%) to 30% (SD 9.8%). Improvement to >35% was seen in 21% of patients. Those who improved to >35% had fewer ICD interventions than those who did not (23 vs.38%; P-value 0.03). Analysing only patients with a primary prevention indication and stratifying again in patients with and without improvement of LVEF to >35%, the latter had highly significant more ICD-therapies (6 vs. 31%; P-value 0.0008).

Conclusion: Patients with CRT-D for primary prevention, whose LVEF improved to >35% during mid-term follow-up, are at low risk of first ICD therapies beyond year 1. If similar findings are reported in other patient cohorts, this might impact on decision-making at the time of battery depletion.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Arrhythmias, Cardiac / epidemiology*
  • Arrhythmias, Cardiac / pathology
  • Cardiac Resynchronization Therapy*
  • Defibrillators, Implantable*
  • Female
  • Health Status Indicators
  • Heart Failure / diagnostic imaging
  • Heart Failure / mortality
  • Heart Failure / therapy*
  • Humans
  • Incidence
  • Male
  • Middle Aged
  • Netherlands / epidemiology
  • Primary Prevention
  • Prospective Studies
  • Registries
  • Risk Factors
  • Risk Reduction Behavior
  • Secondary Prevention
  • Stroke Volume
  • Switzerland / epidemiology
  • Treatment Outcome
  • Ultrasonography
  • Ventricular Function, Left*
  • Young Adult