Automated intracranial aneurysm isolation and quantification

Annu Int Conf IEEE Eng Med Biol Soc. 2010:2010:2841-4. doi: 10.1109/IEMBS.2010.5626075.

Abstract

Until today, geometrical descriptors of intracranial aneurysms are largely used for diagnosis and treatment selection. Nevertheless, relatively little work has been devoted to automatize these measurements. In this work we propose a methodology for the automated isolation and quantification from vascular segmentation. The proposed methodology is based on skeleton topology analysis, geometrical analysis and deformable models to isolate, automatically, the aneurysm dome as well as its geometrical characteristics. The accuracy of this methodology when compared to manually isolated aneurysms is evaluated in 10 patient-specific vascular geometries. Good correspondence is observed between manual and automated results.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Algorithms
  • Aneurysm
  • Automation
  • Computer Simulation
  • Diagnostic Imaging / methods
  • Humans
  • Image Processing, Computer-Assisted
  • Intracranial Aneurysm / diagnosis*
  • Intracranial Aneurysm / physiopathology*
  • Models, Anatomic
  • Models, Theoretical
  • Reproducibility of Results
  • Signal Processing, Computer-Assisted
  • Software