Prospective validation of standardized, 3-dimensional, quantitative coronary computed tomographic plaque measurements using radiofrequency backscatter intravascular ultrasound as reference standard in intermediate coronary arterial lesions: results from the ATLANTA (assessment of tissue characteristics, lesion morphology, and hemodynamics by angiography with fractional flow reserve, intravascular ultrasound and virtual histology, and noninvasive computed tomography in atherosclerotic plaques) I study

JACC Cardiovasc Interv. 2011 Feb;4(2):198-208. doi: 10.1016/j.jcin.2010.10.008.

Abstract

Objectives: This study sought to determine the accuracy of 3-dimensional, quantitative measurements of coronary plaque by computed tomography angiography (CTA) against intravascular ultrasound with radiofrequency backscatter analysis (IVUS/VH).

Background: Quantitative, 3-dimensional coronary CTA plaque measurements have not been validated against IVUS/VH.

Methods: Sixty patients in a prospective study underwent coronary X-ray angiography, IVUS/VH, and coronary CTA. Plaque geometry and composition was quantified after spatial coregistration on segmental and slice-by-slice bases. Correlation, mean difference, and limits of agreement were determined.

Results: There was significant correlation for all pre-specified parameters by segmental and slice-by-slice analyses (r = 0.41 to 0.84; all p < 0.001). On a segmental basis, CTA underestimated minimal lumen diameter by 21% and overestimated diameter stenosis by 39%. Minimal lumen area was overestimated on CTA by 27% but area stenosis was only underestimated by 5%. Mean difference in noncalcified plaque volume and percent and calcified plaque volume and percent were 38%, -22%, 104%, and 64%. On a slice-by-slice basis, lumen, vessel, noncalcified-, and calcified-plaque areas were overestimated on CTA by 22%, 19%, 44%, and 88%. There was significant correlation for percentage of atheroma volume (0.52 vs. 0.54; r = 0.51; p < 0.001). Compositional analysis suggested that high-density noncalcified plaque on CTA best correlated with fibrous tissue and low-density noncalcified plaque correlated with necrotic core plus fibrofatty tissue by IVUS/VH.

Conclusions: This is the first validation that standardized, 3-dimensional, quantitative measurements of coronary plaque correlate with IVUS/VH. Mean differences are small, whereas limits of agreement are wide. Low-density noncalcified plaque correlates with necrotic core plus fibrofatty tissue on IVUS/VH.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't
  • Validation Study

MeSH terms

  • Calcinosis / diagnostic imaging
  • Coronary Angiography / methods*
  • Coronary Artery Disease / diagnostic imaging*
  • Female
  • Fibrosis
  • Georgia
  • Humans
  • Imaging, Three-Dimensional*
  • Male
  • Middle Aged
  • Necrosis
  • Predictive Value of Tests
  • Prospective Studies
  • Radiographic Image Interpretation, Computer-Assisted
  • Reference Standards
  • Reproducibility of Results
  • Scattering, Radiation
  • Tomography, X-Ray Computed*
  • Ultrasonography, Interventional*