Quantification of supra-aortic arterial wall inflammation in patients with arteritis using high resolution dynamic contrast-enhanced magnetic resonance imaging: initial results in correlation to [18F]-FDG PET/CT

Invest Radiol. 2011 Sep;46(9):594-9. doi: 10.1097/RLI.0b013e31821c44ed.

Abstract

Objectives: : To compare [F]- -fluoro-D-glucose (FDG) positron emission tomography (PET)/computed tomography (CT), used in clinical routine to detect inflamed arteries in patients with arteritis, with high resolution dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) in its ability to measure inflammation in carotid and vertebral arteries.

Materials and methods: : This study was performed with written informed consent, Health Insurance Portability and Accountability Act (HIPAA) compliance, and institutional review board approval. DCE-MRI of the carotid and vertebral arteries of 17 patients with suspected arteritis was acquired at 3T (2D saturation-recovery spoiled gradient echo, in plane resolution 0.625 × 0.625 mm) using a dedicated 4-channel carotid coil. Patients underwent [F] FDG-PET/CT within 1 week of the MRI scan. The blood pool-corrected mean standardized uptake value (mean target-to-background ratio [TBRmean]) was measured on PET/CT images at the identical location as the region-of-interest in the magnetic resonance images. MRI signal intensity data was analyzed to generate estimates of the tissue extraction fraction and interstitial volume using a 2-compartment model.

Results: : [F]-FDG PET/CT TBRmean was significantly higher in patients with than without arteritis (1.55 ± 0.34 vs. 1.06 ± 0.14, P = 0.001). Patients diagnosed with arteritis had significantly higher extraction fractions as measured by DCE-MRI than patients without arteritis (8.79% ± 2.19% vs. 5.82% ± 1.13%, P = 0.002). TBRmean correlated significantly with the extraction fraction (r = 0.73, P < 0.001). DCE-MRI and FDG-PET/CT yielded the same sensitivity (86%) and specificity (90%) for the detection of arteritis. Intra- and interreader reproducibility was good with Intraclass Correlation Coefficients of 0.82 and 0.78, respectively.

Conclusions: : DCE-MRI is able to measure arterial inflammation reliably and noninvasively with good correlation to [F]-FDG PET/CT in patients suffering from arteritis of the supraaortic arteries.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Arteritis / diagnostic imaging
  • Arteritis / pathology*
  • C-Reactive Protein
  • Carotid Arteries / diagnostic imaging
  • Carotid Arteries / pathology*
  • Confidence Intervals
  • Contrast Media*
  • Female
  • Fluorodeoxyglucose F18
  • Humans
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Positron-Emission Tomography / methods
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Statistics, Nonparametric
  • Tomography, X-Ray Computed / methods
  • Vertebral Artery / diagnostic imaging
  • Vertebral Artery / pathology*

Substances

  • Contrast Media
  • Fluorodeoxyglucose F18
  • C-Reactive Protein